8 servicing – Glow-worm Hideaway 80CFF User Manual

Page 22

Advertising
background image

22

2000225006B

MAIN
BURNER

GRAPHITE
COATED
NUT(2)

SUPPLY
FEED
PIPE

Diagram 8.10

Diagram 8.9

BURNER
SUPPORT
BRACKET

SCREWS &
NUTS (2)

8.4 Service Checks

Inspect the spark electrode and clean and replace as necessary,
see diagram 8.12.

Check the condition of the side and rear insulation panels in the
combustion chamber.

Check the condition of the seals on the boiler access door and
the combustion chamber cover.

Examine the flue hood and terminal to make sure they are clean
and clear of obstructions.

Refit all parts.

Light the boiler and carry out functional tests as described in
section 6.

Diagram 8.12

ELECTRODE

SECURING
SCREW

+

-

SPARK GAP
= 3.6 1.1

Diagram 8.11

BURNER
INJECTOR

GRAPHITE
COATED
NUT(2)

0939

8 Servicing