Instructions for use – Glow-worm Hideaway 80CFF User Manual

Page 4

Advertising
background image

4

2000225006B

To Turn the Appliance On

Turn the electrical supply on to the boiler and check that all
remote controls are calling for heat.

Turn the boiler temperature control clockwise to any position
between “0” and "Max", see diagram 1.
"MAX" is approximately 82°C (180°F).

The boiler lighting operation is now automatic as follows:

The fan operates and after a short period of time, the spark
ignition operates, the solenoid opens, then the burner will light
shown by the burner ON neon (green) on the control panel
lighting up.

The burner will remain alight until switched off by the control
thermostat or any remote control.

Note: If the boiler is turned OFF at the boiler temperature
control, wait at least 30 seconds before switching on again.

When the boiler switches off, the burner will go out.

The automatic lighting sequence will operate again when heat
is required.

It should be noted that this is a fanned flue appliance and fan
operation may be heard.

If the reset neon lights, turn the boiler temperature control to "0"
(off), wait 30 seconds, then repeat the lighting instructions.

To Turn the Appliance Off

For short periods, turn the boiler temperature control fully anti-
clockwise to “0” (off).

To relight, turn the boiler temperature control to any position
between “0” and “Max”.

For longer periods, turn the boiler temperature control fully anti-
clockwise to “0” (off) and switch off the electrical supply to the
boiler.

To relight follow the lighting sequence given above.

Instructions for Use

Diagram 1

BOILER
TEMPERATURE
CONTROL

9857

"BURNER ON"
NEON

RESET
NEON

"OFF"
POSITION