9 fault finding – Glow-worm Hideaway 80BFF User Manual

Page 24

Advertising
background image

24

221958B

FUSE
TYPE F4A

AIR PRESSURE
SWITCH CONNECTIONS

FAN

EV1

EV2

SPARK
ELECTRODE

AIR
PRESSURE
SWITCH

SL

(N/O) (C)

(N/C)

br

br

bk

p

r

gy

y

br

bk

KEY

bk BLACK
br BROWN
b BLUE
p PURLPLE

r RED
y YELLOW
gy GREY

MAIN TERMINAL
STRIP CONNECTIONS

PRINTED CIRCUIT
BOARD CONNECTIONS

b

b

b

N

b

N

MAINS SUPPLY
230v ~ 50Hz

9.1 Electrical

Gain access to the control box, refer to the relevant paragraph
in section 6.1, then remove the control box cover, refer to
section 5.1.

Refer to: Boiler Fault Finding, see diagram 9.1, Fault Finding
Wiring Diagram, see diagram 9.3, Pictorial Wiring Diagram, see
diagram 9.4.

9.2 Electrical Supply Failure

Failure of the electrical supply will cause the burner to go out.
Operation will normally resume on the restoration of the electrical
supply.

If the burner does not relight after an electrical supply failure and
the red neon on the control panel is lit, turn the burner temperature
control to “0”, wait 30 seconds, then fully clockwise to “Max.”
see diagram 9.2.

Diagram 9.3

10084

9 Fault Finding

Diagram 9.2

BOILER TEMPERATURE
CONTROL

0900