9 Fault Finding

Diagram 9.2

Diagram 9.2A

THERMOCOUPLE FAULT FINDING

4634

Is the connection between the
thermocouple and the multi-functional
control clean and tight ?
See diagram 9.2A, "Connection A"

Clean contacts and re-connect

Is the pilot flame correct length?
Approxomately 12mm.

Check pilot injector and regulate pilot

Check the thermocouple output
(8-15mV, closed) or replace thermocouple.
Reference should be made to procedure 7,
British Gas Multimeter Instruction Book.
Does the pilot now stay alight ?

Change multi-functional control

YES

NO

YES

NO

NO

3816

MULTI-FUNCTIONAL
CONTROL

CONNECTION 'A'

9.1 Pilot

Refer to Chart 9.1.

9.2 Thermocouple

To test the thermocouple a meter with a range of 6 to 30mV is
required together with a thermocouple interrupter test unit.

Refer to thermocouple fault finding chart, diagram 9.2 and
diagram 9.2A.

9.3 Electrical

Important. On completion of the service/fault finding task which
has required the breaking and remaking of the electrical
connections the earth continuity, polarity, short circuit and
resistance to earth checks must be repeated, using a suitable
multimeter.

Refer to Fault Finding, Wiring and Functional Flow diagram 9.3