9 Fault Finding

ELECTRICAL FAULT FINDING

Diagram 9.3

9007

Isolate the supply. Gain access to the control
box, check all connections etc.
Restore supply. Using multimeter set at 230V. AC.

Check supply fuses. Renew if
necessary. If ok then fault lies withtin
remote controls. Inform customer.

With remote controls (if fitted) calling for heat
is there 230V between L &

N

Does main burner light.

Replace multi-functional control harness

YES

NO

YES

NO

Ensure that all services are available at the
appliance. ie. Gas, Electricity, Water.
Also turn control thermostat fully on and
check to see if pilot is lit.

Restore supply. Is there 230V between
"L" & "N" on multi-functional control?

Faulty multi-functional control. Renew.

Does pump run ?

CONTROLS IN ORDER

MAIN TERMINALS STRIP

Isolate supply. Remove gas valve
cover. Check continuity of multi-
functional control wire harness.
Continuity ok ?

Faulty control thermostat. Renew

Faulty pump, inform customer.

YES

YES

YES

YES

NO

NO

NO