Any assistance – Glow-worm Ultrapower sxi User Manual

Page 18

Advertising
background image

0020054593 - 03/11 - Glow-worm

- 18 -

ANY ASSISTANCE ?

ANY ASSISTANCE?

9 Fault Finding

In this section fault codes that are

displayed, which CAN be carried out by

the USER to restore appliance operation

(Corrective action: ...). Other fault codes

MUST be solved by a competent person

only.

Like all condensing boilers

it will produce a plume of

condensation from the flue

terminal in cool weather.

This is due to the high

efficiency and hence low flue

gas temperature of the boiler.

It is normal and not a fault

indication.

If any fault persists, and your appliance still

does not work, leave it switched off and

contact your competent person.

9.1 Electrical Supply Failure

The boiler will not work without an

electrical supply and normal operation

of the boiler should resume when the

electrical supply is restored.
If the boiler does not resume normal

operation, check the external controls.
It may be necessary to reset your

appliance.

• To reset the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

9.2 Appliance fails to light

The LCD will display a flashing 'F' and

code number, see table below.

• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

• If the display shows a flashing pressure

of 0.4bar or less, then you will need to

pressurise the system as described. If

any fault persists, contact your installer/

service provider or Glow-worm Service,

using the telephone number on the

inside back cover of this booklet.

CODE DESCRIPTION

POSSIBLE CAUSES

F1

Boiler has attempted to

light 5 times and failed on

all occassions

Press the reset button.

If the fault persists, contact your Installation/Servicing

company or Glow-worm

F5

Overheat

Boiler has overheated - allow to cool then press reset button