9.5 Protecting against frost

Appliance Protecion

In case of the risk of frost:

• Make sure that the electrical and gas

supply to the appliance is turned on.

• For an absence of several days, you

can leave the appliance to run normally.

The appliance has a built in frost

protection device that protects the boiler

from freezing. With the gas and electric

supplies ON and irrespective of any room

thermostat setting, the frost protection

device will operate the pump when the

temperature of the boiler water falls

below 8

O

C. A timer is used so that the

temperature can be checked periodically.

After 10 minutes the pump will be stopped

if the temperature is higher than 10

O

C or

has already reached 35

O

C. The burner

will activate if the boiler temperature

does not reach 10

O

C after 30 minutes or

at any time if the temperature drops to

5

O

C. The burner will switch off when the

temperature reaches 35

O

C.

The appliance always has frost protection

active when the power and gas supply are

on.

System Protection

The boiler alone cannot ensure that the

installation is protected against frost.

NOTE: Any other exposed areas of the

system should be protected by a separate

frost thermostat.

In case of prolonged absence, where

power to the dwelling and the boiler is

switched off, contact your Installation/

Servicing company or Glow-worm Service

to have the installation drained or to have

the heating circuit protected by adding an

anti-freeze specially designed for heating

systems.

CAUTION: Your domestic

water circuit (hot and cold) is

not protected by the boiler.

9.6 Condensate Drain Blockage

As a safety feature the boiler will stop

working if the condensate drain becomes

blocked. During freezing conditions this

may be due to the forming of ice in the

condense drain external to the house.

• Release an ice blockage by the use of

warm cloths on the pipe.

The boiler should then restart.

• Contact your Installation/Servicing

company or Glow-worm service if the

fault persists.

Disinfection Cycle

The cylinder has a built in disinfection

cycle which raises the water temperature

to 70

o

C for 1 hour every Wednesday at

2:00am.

9.7 Safety Discharge Valve

The safety discharge valve and discharge

pipe is fitted to the boiler.

• If there is any discharge from the pipe,

switch off the boiler electrical supply,

then call your Installation/Servicing

company or Glow-worm service.