7 safety discharge 8 fixing jig – Glow-worm Xtramax User Manual

Page 15

Advertising
background image

15

4000116705-2

9129

Discharge from
HTG prv on jig

Discharge from
DHW safety
valves

Gully

Diagram 7.1

Valve outlet

size

Maximum resistance allowed

expressed as a length of straight

pipe i.e. no elbows or bends

Resistance created

by each elbow

or bend

Minimum size of discharge

pipe D2 from tundish

Minimum size of

discharge to tundish

D1

G 1/2

15 mm

22mm

up to 9 m

0.8 m

28 mm

up to 18 m

1.0 m

35 mm

up to 27 m

1.4 m

G 3/4

22 mm

28 mm

up to 9 m

1.0 m

35 mm

up to 18 m

1.4 m

42 mm

up to 27 m

1.7 m

G 1

28 mm

35 mm

up to 9 m

1.4 m

42 mm

up to 18 m

1.7 m

54 mm

up to 27 m

2.3 m

Discharge pipe (D2) from
turndish with continuous fall see table
above for size examples.

Discharge pipe (D1) from
temperature relief valve to turndish

Tundish
(Supplied)

Fixed grating

Trapped
gully

Safety
device eg.
temperature
relief valve

500mm
max.

300mm min.

9131

7 Safety Discharge

8 Fixing Jig

D1

D2

The fixing jig is made up, from left to right, as follows:
A - Heating return fitting with isolating valve (v) and drain knob (u).
B - Cold water inlet fitting with isolating valve (m) and factory fitted flow restrictor and filter (not shown).
C - Heating flow fitting with isolating valve (q) drain knob (r) and safety valve (10).
D - Domestic hot water outlet.
E - Gas service cock.

Diagram 8.1

9126

Tundish
(Supplied)

u

m

v

q

r

10

A

B

C

D

E

9317

9317

(Fitted inside) Flow
restrictor and cold water
inlet filter

Advertising