20 replacement of parts – Glow-worm Xtramax User Manual

Page 37

Advertising
background image

37

4000116705-2

20 Replacement of Parts

20.10 Three-way valve head

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Locate 3- way valve in centre of lower controls area.

• Remove electrical plug from valve head.

• Pull out slotted metal clip from valve body and remove valve
head from body.

• Fit replacement valve head.

Note :

1) When refitting clip, ensure that letters OK are as shown, see
diagram 20.8.

2) It is not necessary to drain boiler to carry out this work.

20.11 Three-way valve/bypass housing

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Drain down central heating and domestic hot water circuit of
boiler only, see diagram 20.1.

Note: It is not necessary to drain down entire heating system to
carry out this work.

• Remove 3-way valve head, refer to Section 20.10.

• Remove domestic hot water plate to plate heat exchanger,
refer to Section 20.9.

• Undo pipe connection from 3-way valve/bypass housing to
primary heat exchanger, see diagram 20.9.

• Pull out slotted metal clips and remove bypass pipe.

• Pull out slotted metal clip and remove domestic pipe from 3-
way valve/bypass housing to storage vessel.

• Remove central heating flow pipe from 3-way valve/bypass
housing to fixing jig.

• From underneath boiler, undo two screws securing 3-way
valve/bypass housing and lift out of boiler.

• Fit replacement 3-way valve/bypass housing.

20.12 Bypass

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Drain down central heating water circuit of the boiler only, see
diagram 20.1.

Note: it is not necessary to drain down the entire heating system
to carry out this work.

• Pull out slotted metal clips and remove bypass pipe.

• Pull out slotted metal clip securing bypass into bypass housing,
remove bypass.

• Fit replacement bypass.

Diagram 20.8

Pho483

Diagram 20.10

11765

Diagram 20.9

9349

PIPE CONNECTION

20.13 System water pressure sensor

Before starting refer to the front of Section 20 Important
information.

• Remove the front panel, refer to Section 17.3.

• Lower the control panel, refer to Section 17.5.

• Drain down central heating water circuit of the boiler only, see
diagram 20.1.

• Locate system pressure sensor at front left hand side of boiler,
see diagram 20.10.

• Remove electrical connections from sensor.

• Pull off slotted metal clip and remove sensor from boiler.

• Fit replacement sensor.

Advertising