1 technical data – Glow-worm Xtramax User Manual

Page 9

Advertising
background image

9

4000116705-2

1 Technical Data

Heating input

adjustable from 12,5 kW

to 30,3 kW

from 42,650 BTU/H

to 103,383 BTU/H

Heating output

adjustable from 10,4 kW

to 27,6 kW

from 35,484 BTU/H

to 94,170 BTU/H

Efficiency

82 %

Maximum heating temperature

87 °C

Expansion vessel effective capacity

8 l

Expansion vessel charge pressure

0,5 bar

Maximum system capacity at 75°C

180 l

Safety valve,

maximum service pressure 3 bar

Products outlet diameter

60 mm

Fresh air inlet diameter

100 mm

Ø Burner injector

1,20 mm

Inlet pressure

20 mbar

Maxi. Burner pressure

13,8 mbar

Mini. Burner pressure

2,16 mbar

Gas rate maximum

3,20 m

3

/h

Gas rate minimum

1,32 m

3

/h

Heating

Heating input

adjustable from 12,5 kW

to 30,3 kW

from 42,650 BTU/H

to 103,383 BTU/H

Hot water output, automatically variable from 10,4 kW

to 27,6 kW

from 35,484 BTU/H

to 94,170 BTU/H

Storage capacity

43 l

Maximum hot water temperature

60 °C

Minimum hot water temperature

37°C

Specific flow rate

(for 35°C temp rise)

11,4 l/min.

Threshold flow rate

1 l/min.

Nominal water flow rate

11,3 l/min.

Temp./pressure relief valve opening pressure

7 bar

Temp./pressure relief valve opening temperature 90°C
Cylinder heat up time

4 min.

Time to reheat 70% of storage to 60°C

5 min.

Expansion valve setting

6 bar

Expansion vessel charge pressure

3.5 bar

Maximum operating pressure

3.5 bar

Maximum supply pressure

16 bar

Minimum operating pressure

0,7 bar

Weight of appliance when empty

71 kg

Weight of appliance when full

110 kg

Hot water

Electrical supply

230 V

Maximum absorbed power

235 W

Level of protection

IP44

Fuse rating

3A

Natural Gas (G20)

Ø Burner injector

0,77 mm

Inlet pressure

29 mbar

Maxi. Burner pressure

23,8 mbar

Mini. Burner pressure

3,6 mbar

Gas rate maximum

2,39 kg/h

Gas rate minimum

0,99 kg/h

Butane Gas (G30)

Ø Burner injector

0,77 mm

Inlet pressure

37 mbar

Maxi. Burner pressure

30,8 mbar

Mini. Burner pressure

3,6 mbar

Gas rate maximum

2,35 kg/h

Gas rate minimum

0,97 kg/h

Propane Gas (G31)

Electrical

The Seasonal Efficiency Domestic Boilers UK (SEDBUK)
is, "D" 78.9%.

The value is used in the UK Government's Standard Assesment
Procedure (SAP) for energy rating of dwellings. The test data
from which it has been calculated have been certified by B.S.I.

The

XTRAMAX is delivered in three

separate packages:
• The boiler
• The fixing jig
• The flue system

Hab322

Diagram 1.1

WEIGHT 71 kg

480

600

131

890

234

Advertising