Do not use this log set if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the appliance and to replace any
part of the control system and any gas control
which has been under water.

The gas log set must be isolated from the gas
supply piping system by closing its individual shutoff
valve during any pressure testing of the gas supply
system at test pressures equal to or less than 1/2
psig. The gas log set and its individual shutoff valve
must be disconnected from the gas supply piping
system when testing at pressures in excess of 1/2
psig.

Keep the area of the gas log set clear and free from
combustible materials, gasoline and other flam-
mable vapors and liquids.

MAINTENANCE: Periodically remove the logs
and examine the burner assembly. If dirty, clean
with a soft brush. Also examine area around burner
air shutter, and pilot. Any dirt or lint in this area
should be removed. This will insure long life and
trouble-free operation. An annual inspection and
cleaning of the vent system by a qualified agency is
recommended.

The minimum inlet gas supply pressure for the
purpose of input adjustment is 5" W.C. for Natural
Gas and 11" W.C. for L.P. Gas. The maximum
inlet gas supply pressure for this burner is
14" W.C. for Natural and L.P. Gas.

A fireplace screen must be in place when the log set
is burning and unless other provisions for combus-
tion air are provided, the screen shall have an
opening(s) for introduction of combustion air.

WHEN GLASS FIREPLACE ENCLOSURES
(DOORS) ARE USED, OPERATE THE GAS
LOG SET WITH THE GLASS DOORS OPEN.

The minimum size fireplace in which the log set is to
be installed is listed in the Technical Data Table
below.

IMPORTANT INFORMATION

*

For the purpose of this requirement, 39 sq" corresponds approximately to the cross-sectional area of a chimney with
7" diameter, 51 sq" corresponds to 8" diameter and 64 sq" corresponds to 9" diameter.

GOLDEN BLOUNT CSA TECHNICAL DATA TABLE

Log Set

Minimum Fire Box Dimensions

Chimney

Vent

*

BTU Rating

Size

Front Opening

Rear Width

Depth

Height

Height

Opening

Nat.

L.P.

16"

25"

14"

13"

18"

10'

39 sq"

80,000

70,000

18"

27"

17"

13

1

2

"

18"

10'

46 sq"

80,000

70,000

21"

30"

20"

13

1

2

"

18"

10'

46 sq"

80,000

70,000

24"

33"

22"

14"

18"

10'

51 sq"

80,000

70,000

30"

39"

26"

15"

18"

10'

64 sq"

80,000

70,000

36"

45"

32"

15"

18"

10'

64 sq"

80,000

70,000

2

IMPORTANT: MINIMUM VENT OPENINGS IN
TABLE BELOW ARE MINIMUM STANDARDS.
FIREPLACE DAMPERS MUST BE FULLY
OPENED WHEN LOGS ARE IN OPERATION.
LOGS MUST BE INSTALLED IN FIREPLACES
CAPABLE OF BURNING WOOD FIRES.