Big tex” specifications components parts – Golden Blount BIG TEX User Manual

Page 2

Advertising
background image

MODEL #

MINIMUM

MINIMUM

SEE-THRU

OVERALL

MINIMUM

MINIMUM

REQUIRED

REQUIRED

MINIMUM

HEIGHT

REQUIRED

REQUIRED

WIDTH

DEPTH

DEPTH

WITH LOGS

BTU

GAS PIPING

BT24

34"

20"

24"

18"

80,000

1/2" I.D.

BT30

40"

20"

28"

18"

90,000

1/2" I.D.

BT36

46"

22"

28"

20"

120,000

1/2" I.D.

BT42

52"

22"

28"

24"

140,000

3/4" I.D.

BT48

58"

22"

28"

24"

160,000

3/4" I.D.

BT60

70"

22"

28"

24"

180,000

1" I.D.

BT72

82"

22"

28"

24"

220,000

1" I.D.

2

“BIG TEX” SPECIFICATIONS

Components Parts

ITEM

1. 2-Stage Burner Assembly

2. Silica Sand (Used in raised rear burner – Nat. Gas)

3. Glowing Embers

4. Black Volcanic Cinders

5. Vermiculite (Used in raised rear burner – LP Gas and used

on top of lower adjustable burner – Nat. & LP Gas)

6. Gas Connector

7. Damper Clamp

8. Control Tool (Adjustable lower burner)

2

1

4

3

5

6

7

8

L.P. SETS MUST INCLUDE GB FACTORY INSTALLED SAFETY PILOT KIT

NOTE: “Big Tex” ceramic gas logs are

packaged in separate cartons.

Individual logs and log arranage-

ment instructions are supplied

in log cartons.

*The gas fittings supplied are for what the
factory considers a normal installation.
Some installations may require a longer
connector tube or other fittings available
in most hardware stores.

Flame Carry

Down Tube

Raised Rear

Burner

Lower

Burner

Adjustment

Valve

Lower

Adjustable

Burner

Advertising