IMPORTANT – PLEASE NOTE L.P. GAS MODELS!

MODERATE SOOT ACCuMuLATION IS CONSIDERED

NORMAL FOR L.P. GAS LOGS.

LIGhTING INSTRuCTIONS FOR
“BIG TEx” MODELS SuPPLIED wITh
3 IN 1 GAS CONTROL VALVE OR hIGh
OuTPuT MILLIVOLT CONTROL VALVE
ARE LOCATED ON PAGE 4 OF ThESE
INSTRuCTIONS.

To Install Gas Log Set:

1. Attach damper clamp to fireplace damper to

prevent damper from being fully closed.

2. Position burner assembly into fireplace and

position in center and as far toward the rear

as possible (See “Big Tex” Specifications for

allowable dimensions).

3. Attach aluminum connector to gas supply

line and connect to burner assembly. Use

soapy water to check connections for leaks.

4. Pour silica sand into raised rear burner

completely covering pipe in pan. For LP Gas

models, use vermiculite instead of sand.

(Figure 3-1)

5. Place glowing ember material over sand

(vermiculite LP).

(Figure 3-2)

6. Pour vermiculite over lower adjustable

burner.

(Figure 3-3)

7. Place glowing ember material over

vermiculite and upward covering sheet

metal deflector.

(Figure 3-4)

8. Spread the black volcanic cinders in front

of and on sides of adjustable lower burner.

(Figure 3-5)

9. Position bottom front log on grate. Front

log position should be as forward as

possible to allow proper space for flame

carry down tube. (Figure 3-6)

10. Position rest of logs on grate using log

arrangement sheet supplied with logs.

Figure 3-1

Figure 3-2

Figure 3-3

Figure 3-4

Figure 3-5

Figure 3-6

YOu ARE NOw READY TO LIGhT ThE LOG SET BY TuRNING ThE FIREPLACE GAS VALVE ON AND uSING A LONG MATCh
OR BuTANE LOG LIGhTER. LIGhT RAISED REAR BuRNER FIRST BY POSITIONING MATCh OR LIGhTER JuST OVER
RAISED REAR BuRNER whILE TuRNING ON GAS VALVE. AFTER RAISED REAR BuRNER LIGhTS, YOu CAN uSE CONTROL
TOOL FOR LOwER ADJuSTABLE BuRNER TO DESIRED FLAME hEIGhT. A MODERATE FIRE DuRING ThE FIRST 4 hOuRS
OF BuRN TIME IS RECOMMENDED. DO NOT OVERFIRE AT ANYTIME.

DAMPER MUST BE IN FULL OPEN POSITION

BEFORE LIGHTING