For your safety, read before lighting, Shut off procedure – Golden Blount BIG TEX User Manual

Page 4

Advertising
background image

4

ALL GOLDEN BLOuNT GAS LOG PRODuCTS uSING ThE 3 IN 1 GAS CONTROL VALVE CAN BE EASILY CONVERTED TO AN
OFF/ON SOLENOID OR AN ADJuSTABLE MOTOR FLAME hEIGhT. ASK YOuR DEALER OR CALL 1-800-833-1139.

FOR YOUR SAFETY, READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

1. This product has a standing pilot, which must be lit by hand. When lighting the pilot, follow these instructions exactly.

2. This installation should be installed including provisions for combustion and ventilation air, must conform with local

codes or, in the absence of local codes, to the National Fuel Gas Code, ANSI Z223 latest edition.

3. This product must be on a gas supply line that is less than 1/2 psi. and with an individual manual shut off.

4. Never operate this new system with the glass fireplace enclosures (doors) in the closed position.

5. Connecting 110-volt electrical power to this product will cause damage and will void warranty.

3 IN 1 GAS CONROL VALVE LIGHTING INSTRUCTIONS

Pilot Gas and Lighting Procedure

DAMPER MuST BE FuLLY OPENED

1. Turn the gas control knob counter-clockwise to the

PILOT position, push the gas control valve IN and HOLD

in position. This will open the pilot valve and allow gas to

flow to the pilot burner.

2. Light the pilot burner while holding the gas control knob

in until a strong pilot flame is present (approximately 60

seconds).

3. Release the gas control knob. The gas control knob will hold in and engages the valve power unit.

4. Turn the gas control knob counter-clockwise to the ON position. The main burner valve will open and the main

burner will ignite.

Shut Off Procedure

1. To shut OFF the main burner but leaving the pilot ON, turn the gas control knob clockwise to the PILOT position.

This action will close the main gas flow.

2. To shut OFF the main burner and pilot, turn the gas control knob clockwise to the OFF position. This action will

close the main gas valve and disengages the safety pilot valve. However, the power unit must drop out before the light-

ing sequence can begin again. This may take as long as 3 minutes.

3. To relight the pilot, follow the steps in the Pilot Gas and Lighting Procedure section.

Pilot burner location

LP Gas models

Pilot burner location

Nat. Gas models

Pilot Adjustment

Gas Control Knob

Removable Plug

for ON/OFF Solenoid

or hI/LO Adjustable

Motor Installation

Advertising