Accessories, Electrical connections – Datalogic Scanning DS8100A-3002 User Manual

Page 4

Advertising
background image

DS8100A-3002 QUICK GUIDE

4

Accessories:

NAME Description

Part

Number

PWO-480

Power and Connect System 480W

93ACC1767

FS-1

Frame Shaper (8 pcs)

93ACC1750

FBK-8100

Fast Bracket Kit (2 pcs)

93ACC1130

US-8100

Bracket Kit (10 pcs)

93ACC1140

GFC-80

90 Degree Mirror

93A251020

GFC-800

90 Degree Close Distance Mirror

93A201103

S30 Photocell

Kit

93ACC1782

PH-1

Photocell Kit - PNP

93ACC1791

MEP-543

Photocell Kit - NPN

93ACC1728

OEK-2

Optical Encoder Kit (10 m cable + spring)

93ACC1770

OEK-1

Optical Encoder Kit + 10 m cable

93ACC1600

BTK-8100

Bus Terminator Kit (5 pcs)

93ACC1090

BTK-8500

IP65 Terminator Kit (2 pcs)

93A051286

PLL-8000

Optocoupled PLL device

93ACC1280

CAB-8100

10 wire shielded cable D 9.5 mm – 50 m

93ACC1120

CAB-8101

17-pin scanner/scanner connection cable 1.2 m

93A051020

CAB-8102

17-pin scanner/scanner connection cable 2.5 m

93A051030

CAB-8105

17-pin scanner/scanner connection cable 5 m

93A051040

CAB-8501

IP65 Cable Fam 8K 1,2 m

93A051283

CAB-8502

IP65 Cable Fam 8K 2,5 m

93A051284

CAB-8505

IP65 Cable Fam 8K 5 m

93A051285

Datalogic WebSentinel-005

Supervisor (up to 5 arrays)

93A101014

Datalogic WebSentinel-010

Supervisor (up to 10 arrays)

93A101015

Datalogic WebSentinel-020

Supervisor (up to 20 arrays)

93A101016

Datalogic WebSentinel-032

Supervisor (up to 32 arrays)

93A101017

Datalogic WebSentinel-064

Supervisor (up to 64 arrays)

93A101018

Datalogic WebSentinel-128

Supervisor (up to 128 arrays)

93A101019

Datalogic WebSentinel-256

Supervisor (up to 256 arrays)

93A101020


Electrical Connections:


Two 17-pin connectors provide access to the scanner’s local Lonworks network used for both input and output
connections to build a multi-sided or omni-station system.

17-pin Lonworks Connector Pinout

Pin Name

Function

A1

GND

Supply voltage (negative pin)

A2

VS

Supply voltage 20 to 30 Vdc (positive pin)
Cable shield A - internally connected by

1 CHASSIS

capacitor to chassis

2 n.c.

Not

connected

Cable shield B - internally connected by

3 CHASSIS

capacitor to chassis

4 TXAUX

Transmit data of auxiliary RS232
(referred to SGND)

5

SGND

Signal ground (connected to GND)

6 RXAUX

Receive data of auxiliary RS232
(referred to SGND)

7

VS_I/O

Supply voltage of I/O circuit

8

Lon A+

Lonworks a line (positive pin)

9

Lon A-

Lonworks a line (negative pin)

10

Lon B+

Lonworks b line (positive pin)

11

Lon B-

Lonworks b line (negative pin)

12 SYS_I/O

System

signal

13 SYS_ENC_I/O System

signal

14 Reserved

Internally

connected

15 Ref_I/O

Reference voltage of I/O circuit

A1

A2

1

15

Female - Output

A1

A2

1

15

Male - Input

17-pin Local Lonworks Connectors

Advertising