Installation instructions, Engineering considerations, Lamps operated – IOTA I-42-L User Manual

Page 2: Mounting the i-42-l and battery, Conditions of acceptability, Illustration 1 illustration 2 - tbts, Page 2

Advertising
background image

Page 2

+ RED
LEAD

WHITE

LEAD

Mounting

Barrier

Leave space

between boards

Use – For use only in complete equipment or final applications where the acceptability of the combination is deter-

mined by Underwriters Laboratories, Inc.

These components have been judged on the basis of the required spacings in the Standard for Emergency Lighting

and Power Equipment UL 924, Sec. 29, which covers the end use product for which the component was designed.

CONDITIONS OF ACCEPTABILITy

1. Installed in a suitable ultimate enclosure.
2. Used with marked electrical ratings.
3. Provide with proper spacing between live parts and enclosure and/or adjacent devices.
4. Factory wired only (terminations not suitable for field wiring).
5. Temperature tests may have to be repeated where battery temperature exceeds 50° C.
6. Mounted within the end-use product such that the battery is secured and the test switch operates properly

when the end product is fully assembled.

7. End-use products employing one or more of these devices are to be marked in accordance with the Standard

for Emergency Lighting and Power Equipment, UL 924.

INSTALLATION INSTRUCTIONS

CAUTION: Before installing, make certain the A.C. power is off and the I-42-L unit connector is disconnected.

1. LAMPS OPERATED

Refer to the chart below for the type of lamp(s) operated and the number of lamps to be operated in the emergency mode.

If you have any questions regarding specific lamps, contact customer service.

INSURE WIRING IS IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL REGULATIONS.

The

6

″ violet leads provide the lamp selection option. The unit is shipped from the factory with the leads

disconnected and capped. When used with particular lamp types, violet leads should be connected to one anoth-
er. Refer to chart for lamp selection options.

2. MOUNTINg ThE I-42-L AND BATTERy

Mount

the

I-42-L in the ballast channel or enclosed wireway so the wire leads are not exposed, at least

1

/

2

away

from the A.C. ballast(s). Mount the

I-42-L using the mounting holes provided. The insulating barrier should be

mounted against the fixture wall. Then the main circuit board can be mounted leaving a space between the board

and the mounting barrier as shown in Illustration 1. The circuit board should be placed so that no live parts are ac-

cessible during routine maintenance or relamping.

The battery should be at least

1

/

2

″ from the A.C. ballast and other heat sources. Since heat rises, try to mount the

battery as low as possible.

CAUTION

– Connect the battery to the unit before applying A.C. power.

N

O

I

T

P

O

P

M

A

L

E

P

y

T

y

C

N

E

g

R

E

M

E

N

O

I

T

A

R

E

P

O

T

E

L

O

I

V

S

D

A

E

L

1

2

3

4

10W-18W

26W-42W

18W

One Lamp

One Lamp

Two Lamp

Two Lamp

Compact

Compact

Compact

Compact

Connected

Disconnected

Connected

Disconnected

10W-13W

5

6

7

18W

24W

36W

Long

Compact

Long

Compact

Long

Compact

One Lamp

One Lamp

One Lamp

Connected

Disconnected

Disconnected

ENGINEERING CONSIDERATIONS

Illustration 1

Illustration 2 - TBTS

OBSERVE PROPER
POLARITy

Advertising