IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.

CAUTION – To prevent electrical shock, do not mate unit connector until full installation is complete and A.C.

power is supplied to the unit.

2.

CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical

shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by discon-

necting the unit connector.

3.

CAUTION – This is a sealed unit. Components are not replaceable. Replace the entire unit when necessary.

4.

CAUTION – Installation and servicing should be performed by qualified personnel only. Do not open this

unit.

5.

DO NOT USE OUTDOORS. The ILB-1826 is for use with grounded, UL Listed, damp location rated fixtures.

Not for use in heated air outlets or hazardous locations.

6. The

ILB-1826 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused

A.C. lead.

7. The

ILB-1826 and LED driver must be on the same branch circuit.

8. Do not mount near gas or electric heaters.

9. The

ILB-1826 should be mounted in locations and at heights where it will not readily be subjected to tamper-

ing by unauthorized personnel.

10. The

ILB-1826 will supply up to 24 Watts for 90 minutes. Output current may vary depending on the ILB model.

Refer to model specifications for output current ratings.

11. The

ILB-1826 is supplied with a 16.8VDC @ 2500mAh nominal battery (14 C cells of 2.5 Ahs).

12. Suitable for use in damp locations.
13. Acceptable operating temperatures are as follows:

Non-Cold Weather Battery Pack - For use in 32° F minimum, 131° F maximum ambient temperatures.
Cold Weather Battery Pack - For use in -4° F minimum, 131° F maximum ambient temperatures.

14. The

ILB-1826 is compatible with most appropriately rated LED drivers, including LED drivers with multiple

LED arrays, with one LED array operating in the emergency mode.

15. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

16. Do not use this equipment for other than intended use.

17. Install in accordance with the National Electrical Code and local regulations.

18. Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before

final installation.

19. Do not disconnect DC power with AC power supplied. Always disconnect AC power first.

SAVE THESE INSTRUCTIONS

ILB-1826

LED

EmERgENCy

LIghTINg EqUIPmENT

INSTRUCTION MANUAL

P.O. BOX 11846 TUCSON, AZ 85734

(520) 294-3292 • FAX (520) 741-2837

www.iotaengineering.com

Advertising