IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

1.

CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power
is supplied to the unit.

2.

CAUTION – This fixture provides more than one power supply output source. To reduce the risk of
electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by
disconnecting the unit connector.

3.

CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the
entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly.

4. The

ICE-80 is for use with grounded, UL Listed, damp location rated and enclosed and gasketed fixtures. Not for

use in heated air outlets or hazardous locations.

5. The

ICE-80 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused

A.C. lead.

6. Do not mount near gas or electric heaters.
7. The

ICE-80 should be mounted in locations and at heights where it will not readily be subjected to tampering by

unauthorized personnel.

8.

When used in conjunction with enclosed and gasketed fixtures, the ICE-80 is suitable for mounting in

the ballast compartment only.

9. The

ICE-80 will cold strike and operate one 28W or 54W T5 or 2´-8´ T8-T12 or two 2´-4´ T8-T12 instant start,

rapid start, U shape or circline fluorescent lamps, including energy saving and long 4 pin compact lamps for
90 minutes.

10. The

ICE-80 is compatible with most A.C. ballasts (including multiple lamp) as follows:

Magnetic ballasts – either one or two lamp emergency operation.
Electronic ballasts – one lamp emergency operation, consult Customer Service for two lamp emergency opera-
tion wiring diagrams.

11. Suitable for use in damp locations and in enclosed and gasketed fixtures.
12. For use in -18

°

C minimum, 50

°

C maximum ambient temperatures.

13. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
14. Do not use this equipment for other than intended use.
15. Install in accordance with the National Electrical Code and local regulations.
16. Installation and servicing should be performed by qualified personnel.
17. Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility

before final installation.

SAVE THESE INSTRUCTIONS

ICE-80

COLD-WEATHER SERIES D

EMERGENCY

LIGHTING EQUIPMENT

INSTRUCTION MANUAL

P.O. BOX 11846 TUCSON, AZ 85734

(520) 294-3292 • FAX (520) 741-2837

www.iotaengineering.com

Advertising