Typical wiring diagrams, Three lamp rapid start ballast, Four lamp rapid start ballast – IOTA ICE-80 User Manual

Page 4: Page 4, Ice-80

Advertising
background image

Page 4

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED

RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

2LRSB_ICE80_D

TWO LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

TYPICAL WIRING DIAGRAMS

For wiring diagrams of ballasts not shown, consult our Customer Service.

Rev. 071513
68180-041

1. ONE LAMP RAPID START BALLAST

2. TWO LAMP RAPID START BALLAST

3. TWO LAMP RAPID START BALLAST

4. THREE LAMP RAPID START BALLAST

7. ONE LAMP INSTANT START BALLAST

8. TWO LAMP INSTANT START BALLAST

9. THREE LAMP INSTANT START BALLAST

10. FOUR LAMP INSTANT START BALLAST

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

1LRSB_ICE80_D

ONE LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

RED OR RED/BLK (+)

BLK/ORG

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

TBTS / CHARGE

INDICATOR

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE/WHT

BLUE/WHT

RED

RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

COMMON

A.C.

Ballast

BLUE

BLUE

EMERGENCY

BALLAST

3LRSB_ICE80_D

THREE LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION IS

COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.

FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.

TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)
BLK (120V)

WHITE

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

RED

ONE LAMP INSTANT START BALLAST

1LISB_ICE80_D

EMERGENCY

BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

RED OR RED/BLK (+)

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

2LISB_2_ICE80_D

TWO LAMP INSTANT START BALLAST

WHT/BLK

WHT/RED

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.


BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

BLUE

RED

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

3LISB_ICE80_D

THREE LAMP INSTANT START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

VIOLET

VIOLET

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMP OPERATION SECTION FOR

VARIOUS OPTIONS.
CONNECT BLU/WHT AND RED/WHT WIRES TOGETHER.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP
LAMP
LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

RED
RED

BLUE
BLUE

YELLOW
YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

4LISB_ICE80_D

FOUR LAMP INSTANT START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

5. THREE LAMP RAPID START BALLAST

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

WHITE

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

RED

RED

RED

RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

COMMON

A.C.

Ballast

THREE LAMP RAPID START BALLAST

BLUE

BLUE

UNIT

CONNECTOR

TBTS/CHARGE

INDICATOR

VIOLET

VIOLET

EMERGENCY

BALLAST

3LRSB2_ICE80_D

BLACK (120V)

BLK/ORG

WHT/RED

RED OR RED/BLK (+)

ORANGE

ORANGE

YELLOW

YELLOW

ORG (277V)

WHT/BLK

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

ICE-80

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

CHARGE

INDICATOR

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

VIOLET

VIOLET

UNSWITCHED

SWITCHED OR

UNSWITCHED

LINE

COMMON

ORG (277V)

BLK (120V)

WHITE

LAMP

*LAMP

*AC / EMERGENCY

BLACK

WHITE

BLUE

BLUE

RED

RED

YELLOW

YELLOW

BLUE

BLUE/WHT

RED/WHT

RED

YELLOW

UNIT

CONNECTOR

TBTS / CHARGE

INDICATOR

COMMON

A.C.

Ballast

EMERGENCY

BALLAST

2LRSB_ICE80_2_D

TWO LAMP RAPID START BALLAST

WHT/BLK

WHT/RED

RED OR RED/BLK (+)

BLK/ORG

ICE-80

CHARGE

INDICATOR

6. FOUR LAMP RAPID START BALLAST

UNSWITCHED

COMMON

WHITE

BLACK (120V)
BLK/ORG

ORG (277V)

WHT/BLK

LAMP

LAMP

LAMP

*LAMP

*AC / EMERGENCY

BLACK
WHITE

BROWN
BROWN

RED

RED

BLU/WHT

BLU/WHT

BLUE

BLUE/WHT

RED

YELLOW

COMMON

A.C.

Ballast

FOUR LAMP RAPID START BALLAST

UNIT

CONNECTOR

TBTS/CHARGE

INDICATOR

VIOLET

VIOLET

EMERGENCY

BALLAST

4LRSB_ICE80_D

WHT/RED

RED OR RED/BLK (+)

RED/WHT

BLUE

BLUE

ORANGE

ORANGE

YELLOW
YELLOW

SWITCHED OR

UNSWITCHED

LINE

SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD.
DO NOT MATE CONNECTOR UNTIL INSTALLATION

IS COMPLETE AND AC POWER IS SUPPLIED.
LAMP SELECTOR LEADS—REFER TO INSTALLATION

INSTRUCTIONS, LAMPS OPERATION SECTION FOR

VARIOUS OPTIONS.
FOR 120V INSTALLATION, CONNECT BLK/ORG TO BLK.

FOR 277V INSTALLATION, CAP BLK/ORG AND BLK

SEPARATELY.
TEST ACCESSORY LEADS-REFER TO INSTALLATION

INSTRUCTIONS FOR PROPER POLARITY WIRING.

ICE-80

CHARGE

INDICATOR

Advertising