TWO-STEP VOLTAGE JACK

The two-step voltage jack allows switching from a long-term
float voltage to a ‘high-stage’ voltage. When the included
dual voltage plug is inserted in the jack*, the voltage rises to
a bulk voltage for occasional fast charging. When the plug
is removed, the voltage drops to the float voltage to reduce
battery water loss (voltages vary depending on the output
ratings of the DLS).

WARNING: To avoid battery damage,

remove the Dual Voltage Plug when quick-charging is
complete.
NOTE: If the unit is equipped with an internal
IQ4 smart charger, two-step charging is not needed and the
Dual Voltage Jack is disabled.

CHARGE CONTROL

THE IQ4 LED INDICATOR

(ONLY ON IOTA mODELS WITH INTERNAL IQ4)

IOTA Models with an internal IQ4 smart-charger give the
user the benefit of automatic Bulk, Absorption, and Float
stage charging. This increases the charging capacity of
the IOTA charger, decreases charge times and insures
proper and safe battery charging without over-charging.
The green LED on the fan end of the unit will indicate which
charging phase the IOTA unit is currently in. When the unit
is first activated, the LED will flash as it reads the number
of cells in the battery. The unit will then proceed directly
to the Bulk charging or Float charging phase depending
on the charge status of the battery. Use the LED CODE
TABLE for reference when checking the LED. Units that do
not have an internal IQ4 smart-charger can easily install
an external IQ4 that plugs into the available Dual Voltage
Jack. Contact Customer Service for more information.

DLS SERIES m

*Actual component locations may vary depending on model.

Location of the Dual Voltage Jack may vary depending on model.

ILLUSTRATION 1 - DLS CONNECTIONS*

ILLUSTRATION 2 - AC INPUT PLUG

ILLUSTRATION 3 - DUAL VOLTAGE JACK

NEMA 6-15P PLUG

FOR 240V 15A RECEPTACLE