11. Product overview

14

PLM+ SERIES Quick Start Guide rev 1.0.0

Use the primary connector when using a star network topology, consisting of individual Cat-5e connections
between the devices and an Ethernet switch. Alternatively, this connection can be used to daisy chain directly to
another Lake Processor. The daisy chain topology should not be used with Dante.

For a technical reference of the Ethernet Port, please refer to the full PLM+ Series Operation Manual. Additional
information is also available in the Lake Network Configuration Guide.

Note: Additional processor configuration is required for a dual redundant network setup. See the Lake
Controller Operation Manual for further details.

Note: Do not create a closed loop when configuring multiple devices in an Ethernet network; this will
cause a network malfunction.

6

Secondary Network Connector – The secondary network connector can be used to daisy-chain multiple

PLM+ Series devices. Alternatively, a Dante dual-network topology can be created by connecting all secondary
network connectors to a separate Ethernet switch, ensuring full redundancy in the event of a network component
failure.

7

Mains Power Connector – AC mains input is via a Neutrik powerCON connector, rated at 32A. Connector

mates with supplied AC mains cable. See previous section on Operating Voltage for more information.