13. Quick Start Tutorial

20

PLM+ SERIES Quick Start Guide rev 1.0.0

18. Tap the Input Gain button in the block diagram and unmute the Module Input Mute. Tap EQ/Levels Exit to return to

IO Config.

19. The left side of the IO config screen holds frame configuration and summary for Clock configuration, Input

configuration, Dante configuration, Breaker Emulation Limiter configuration and Analog Iso-Float & AES Termination

configuration. All these configurations should be correct by default for this example.

20. From I/O CONFIG, tap EVENTS & CONTROL and navigate to the STATUS tab. If muted, unmute the power

channels and slowly increase the volume on the appropriate feed from the mixing console. Audio should now be

active at the outputs and heard through the loudspeakers. Close the Events and Control dialog with the return

button and return to the main area by tapping the I/O Config EXIT button.

Levels Control - Drag sliders and tap mute buttons for module

input and output channels.

Delay Control - Drag sliders to control input and output delay

Crossover control – Select filters and drag on the bottom

frequency bar to adjust crossover frequency. Crossover

types may be changed by selecting the Crossover

Functions button.

Parametric EQ control – Select filter on the top squares

and adjust filter properties by dragging the controls. Sliders

at the bottom control center frequency and Q (bandwidth).

Gain is controlled in the main window area. Additional filters

can be added by tapping the top filter objects and placing

new filters on the main area.

Events & Control, Status tab – Drag sliders to adjust power channel attenuation and tap mute buttons to
control power channel mute. Metering and Status monitoring is available for each power channel.