15. Technical Specifications

PLM+ SERIES Quick Start Guide rev 1.0.0

27

PLM 12K44

PLM 20K44

Gain
Amplifier gain

22 - 44 dB, step size 0.1 dB

22 - 44 dB, step size 0.1 dB

Analog attenuator

- Inf to 0 dB, step size 0.25 dB

- Inf to 0 dB, step size 0.25 dB

Rear-panel interface
Analog inputs

4 x 3 pin XLR, electronically balanced

4 x 3 pin XLR, electronically balanced

AES inputs

2 x 3 pin XLR

2 x 3 pin XLR

Output connectors

Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 binding posts (pairs)

Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 binding posts (pairs)

Auto 100/1000, Auto Uplink

2 x RJ45 etherCON

2 x RJ45 etherCON

Control and monitoring interface

Via Ethernet for Lake Controller software, or DLM (the 3rd

party protocol)

Via Ethernet for Lake Controller software, or DLM (the 3rd

party protocol)

Detachable mains cord

Neutrik powerCON 32 A

Neutrik powerCON 32 A

Cooling

Three fans front-to-rear airflow, temperature controlled speed

Three fans front-to-rear airflow, temperature controlled speed

Front-panel interface
Display

2.5 inch, Black / white, daylight readable LCD

2.5 inch, Black / white, daylight readable LCD

Fault / Warning / Limit / Clip indicators

RGB LED’s and detailed fault description on display

RGB LED’s and detailed fault description on display

Mute and soft function buttons

8 provided

8 provided

Standby Power button

On / Standby

On / Standby

Mute Enable button

Enables muting of outputs and inputs via soft-button keypad

Enables muting of outputs and inputs via soft-button keypad

Meter button

Toggles through meter views

Toggles through meter views

Menu button

Provides a menu driven interface for full function front panel

control

Provides a menu driven interface for full function front panel

control

Rotary Encoder

Yes

Yes

Exit button

Provides a “back” function

Provides a “back” function

Mains power
Nominal voltage

100 - 240 V AC 45- 66 Hz

100 - 240 V AC 45- 66 Hz

Operating voltage

70 - 265 V AC

70 - 265 V AC

Mains wall plug

NEMA L5-30 “Twist lock” 125 V / 30 A, and CEE 7/7

“Schuko” 230 V / 16 A

NEMA L5-30 “Twist lock” 125 V / 30 A, and CEE 7/7

“Schuko” 230 V / 16 A

Power supply features
Soft start / Inrush power

Yes / Max 8 Ampere

Yes / Max 8 Ampere

Power Factor Correction (PFC)

0.98

0.98

Regulated switch mode power supply

Yes

Yes

Breaker Emulation Limiter (BEL)

Configurable current threshold and breaker profile

Configurable current threshold and breaker profile

BEL max current threshold

25 A

32 A

Power Average Limiter (PAL)

Yes

Yes

Under Voltage Limiter (UVL)

Yes

Yes

Mains under voltage and overvoltage protection

and mains glitch tolerance

Yes

Yes

Dimensions
Rack rail to rear panel

W: 483 mm (19”), H: 88 mm (2 U), D: 424 mm (16.7”)

W: 483 mm (19”), H: 88 mm (2 U), D: 424 mm (16.7”)

Overall depth including handles and rear support

D: 498 mm (19.6”)

D: 498 mm (19.6”)

Weight

16.5 kg (36 lbs)

17 kg (37 lbs)

Finish

Black painted steel chassis with black painted steel / aluminium

front

Black painted steel chassis with black painted steel / aluminium

front

Approvals

CE, ANSI / UL 60065 (ETL), CSA C22.2 NO. 60065, FCC,

PSE, RCM, BIS India

CE, ANSI / UL 60065 (ETL), CSA C22.2 NO. 60065, FCC,

PSE, RCM, BIS India

Note 1): Lab.gruppen burst power (1 kHz, 25 ms burst power @ 150 BPM, 12 dB Crest factor)

All specifications are subject to change without notice.

Intercooler, Class TD and Lake are national and/or international registered trademarks of Lab.gruppen AB. PLM, Powered Loudspeaker Management, R.SMPS, LoadLibrary, LoadSmart,
SpeakerSafe, BEL, UVL and ISVPL are trademarks of Lab.gruppen AB. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. Contour, Mesa Quad EQ, Mesa
Parametric EQ, Raised Cosine Equalization, LimiterMax and Iso-Float are trademarks of Dolby Laboratories. Audinate is a registered trademark of Audinate Pty Ltd. Dante and Zen are trademarks
of Audinate Pty Ltd. All other trademarks remain the property of their respective owners.

Copyright © 2014 Lab.gruppen AB.

All rights reserved.