4.2.4

CAN Status Tab

Once you entered the proper values in for the Primary CAN Data (and the Secondary CAN Data if
applicable), you can now connect to the CAN network and see if the CAN data you have selected is
being broadcast.

If the CAN2-002 module is not connected to the PC, connect the two with the USB cable and click on on
the Connection button to connect the module. The connection status indicator should be green and
indicate you are connected to the CAN2-002 module (Online). Make sure the CAN2-002 module is
connected to the CAN bus then and that the network is powered up (ignition on).

Click on the CAN Status tab and you will be brought to this screen in the software:

Click on the "Check CAN Status" button.

The indicator circles after the primary and secondary for each output should now indicate if the selected
CAN message is being broadcast and received by the CAN2 module. A red circle indicates that the
selected CAN message is not being read. A green circle indicates the selected CAN message is being
read by the CAN2-002 module.

If none of your messages show up make sure you have a good CAN bus connection and that the
connection speed is set correctly in the CAN2 module.

If some of your messages do show as valid but others don't then you are receiving CAN data but that
particular message doesn't exist on the CAN bus at that address. Try a different variable of the same
name. If that doesn't work contact LPE or your LPE dealer for additional assistance.