This option is only available if the LinkNet interface has been set up in
auxiliary communications and the network is “online”. When the “Print To
Network” option of the SEND GRAPH softkey is selected, the OmniLink will
retrieve the tonnage waveform from the tonnage monitor and transfer it to the
network host computer. This will result in the tonnage waveform being
automatically printed at the configured printer from the LinkNet host computer.
After success or failure is reported, press any key to resume normal operation
of the screen. Note that this operation is a restricted operation and may require
the RUN/PROG key and/or an access code depending on system configuration
(see section 11 on page 78 for details).

3.5.7 Reference Waveforms

For each job, one reference waveform may be stored. This will typically be a “known good” waveform
representative of a setup that is producing good parts. If a problem, or suspected problem, later comes
up with the job, the reference waveform can be “overlaid” with the current waveform to check for
important differences. See section 3.5.6 for information on storing a reference waveform.

To display a reference waveform, press the SHOW REF GRAPH softkey (as seen in Figure 10). Note
that this softkey will only be displayed if a reference waveform has been previously stored for the
current job. The reference waveform will show in green, overlaid with the current waveform which will
still be in black. Once the reference waveform is displayed, the SHOW REF GRAPH key changes to
HIDE REF GRAPH. Pressing this key again will remove the reference waveform from the screen
leaving only the current waveform.