3 function setting, 4 clearing the total weight – LW Measurements MCT 66 User Manual

Page 21

Advertising
background image

21

18. Press the TOTAL key to switch between normal counting and recalling

memory data.

4.1.3 Function setting

-

Turn off the weighing machine using the hard switch located on the

bottom of the weighing machine.

- Press and hold UNIT WEIGHT key and then turn on the weighing
machine. The display will show

“------“ and then “b = XX” (beeper), on the first line, A-XX (auto off) on the

second line and “L = XX (backlight) on the third line.

- Press the QTY/SET key to toggle between activating the beeper on or
off.

- Press the TARE key to select auto off time.

- Press the ZERO key to toggle between activating the backlight On, Off,

or Auto(AU). To save your settings, and begin weighing, turn the
machine off and then back on again.


- When there is no weight on the platter, press the SAMPLE/UNIT key to

select the weighing unit (kg or lb).

4.1.4 Clearing the total weight

- Press the TOTAL key to show the total pieces on the third line of the
display.

- Press the MC key to show the unit that will be cleared.

- Press the CE key to confirm clear.