Dacor Preference and Millennia RSE30 User Manual

Page 6

Advertising
background image



5. The maximum gas supply

pressure to the appliance gas

pressure regulator must never

exceed 1/2 pound per square

inch (3.5kPa).

NOTE:

The applaince gas pressure

regulator is pre-set at the factory

for the type of gas intended for

use with the appliance. Verify

that the appliance is compatible

with the type of gas available by

checking the data plate located

behind the inlet air cooling grill.

Ranges intended for use with LP

gases will have “LP” as a part

of the model number. Consult

your dealer if the range is not

compatible with your gas supply.

wARNING:

**do not connect the green

appliance wire to the neutral

(white) supply wire unless local

building codes permit.

wARNING:

The RSd30 cannot be connected

as above because it will damage

the spark module.

B. Connecting the Green Appliance wire to

the Neutral (white) Supply wire – where

Local Codes Permit. (RSE/MRES30

Only)

1. Connect the green and white appliance

wires to the neutral (white) supply wire in

the junction box.

2. Connect the black appliance wire to the

black (L1) power supply wire in the junction

box.

3. Connect the red appliance wire to the red

(L2) power supply wire in the junction box.

C. Connecting the Green Appliance wire to

a Grounded Supply wire or a Grounded

Cold water Pipe – where Local Codes

Permit. (All Models)

1. Separate the green and white appliance

wires.

2. Connect the white appliance wire to the

neutral (white) supply wire in the junction

box.

3. Connect the black appliance wire to the

black (L1) power supply wire in the junction

box.

Conduit from

appliance

Cable from

power supply

Wire nut

(3 places)

Junction

box

RED
RED

GREEN

WHITE

WHITE

BLACK
BLACK

**Connecting the appliance to a

three-wire power supply

(RSE/MRES30 Only)

Conduit from

appliance

Cable from

power supply

Wire nut

(4 places)

Junction

box

RED

RED

GREEN

GREEN

WHITE

WHITE

BLACK

BLACK

Separate No. 10 (minimum)

copper grounding wire

Clamp must be

tight on pipe

No. 4

copper wire

Metal

water pipe

Clamps

Bare metal

Meter

Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe

Gas Connection

Before sliding the range into the cabinet,

connect a flexible gas connector to the gas

shut-off valve previously installed on the stub

out. The gas valve must be turned off during

installation. Connect the flex connector to the

pipe fitting at the right rear of the range.

wARNINGS:

1. do not apply excessive

pressure when tightening gas

connections and fittings.

2. do not use teflon tape or

plumber’s putty on gas flex

line connections.

3. Turn all cooktop control valves

to the “OFF” position. Turn

on gas supply and check all

lines and connections for

gas leaks using a soap and

water solution. do not use a

flame to check for leaks. After

verifying that there are no gas

leaks, turn off the gas supply

to the range by turning the gas

shut-off valve to the “OFF”

position.

4. For LP installations, the LP

gas tank must have its own

high pressure regulator. This

is in addition to the pressure

regulator provided with the

range.

Installing the Range

Measure from the floor to the countertop and

adjust the leveling legs as required to position

the top frame at the desired height, based on

the cabinet and countertop installation. Carefully

slide the range into position in the cutout. (The

left rear leveling leg should engage the anti-tip

bracket.)

When the range is to be installed as a “slide-in,

self rimming” (with the range top overhanging

the countertop cutout), measure from the floor

to the countertop. Adjust the leveling legs to

position the bottom edge of the range top frame

approximately 1/8” (13mm) above the level of

the countertop. This will allow the range to slide

over the countertop. Carefully slide the range

into position in the cutout. Again, the left rear

leveling leg should engage the anti-tip bracket.

To lower the range onto the countertop, turn the

leveling legs counterclockwise. Lower the range

until the bottom of the range top just contacts

the countertop. Do not allow the full weight of

the range to hang on the counter.

Installing the Burner Components

Remove the brass burner rings, porcelain burner

caps, and porcelain gates from their shipping

packages. Place each burner ring onto its

corresponding burner base, being certain that

the five alignment tabs slide into the matching

notches in the base. Set each porcelain burner

cap on top of its corresponding burner ring.

Place each grate onto the top frame, being

certain that the rubber feet are positioned in the

locating dimples.

wARNING:

Never attempt to operate the

cooktop section of the range with

any of the burner rings, burner

caps or grates removed.

4. Connect the red appliance wire to the red

(L2) power supply wire in the junction box.

5. Connect the green appliance wire to a

grounded supply wire in the junction box or

to a grounded cold water pipe.

6. If connecting to a grounded cold water

pipe, a separate copper grounding wire

(No. 10 minimum) must be connected to a

grounded cold water pipe by means of a

clamp and then to an external grounding

connector screw.

6. A grounded cold water pipe must have

metal continuity to electrical ground and

must not be interrupted by insulating

materials. Any insulating materials must be

jumped with a length of No. 4 copper wire

securely clamped to bare metal at both

ends.

Advertising