Re-installing the Oven door

Grasp the oven door on opposite sides and

lift it until the door hinges are aligned with the

openings in the oven frame. Holding the door at

about a 30˚ angle from the horizontal, slide the

hinges into the openings until the bottom hinge

arms drop fully into the hinge receptacles. Lower

the door to the fully opened position, and then

rotate the two hinge catches toward the oven.

Open and close the door completely to ensure

that it is properly installed. Peel off the protective

layer of plastic that covers the door panel.

Verifying Proper Gas Operation of

the dual Fuel Ranges (RSd)

wARNINGS:

1. The range and shut-off

valve must be disconnected

from the gas supply piping

during any pressure testing

exceeding 1/2 psi (3.5kPa).

2. The range must be isolated

from the gas supply piping

by closing the shut-off valve

during any pressure testing at

or below 1/2 psi (3.5 kPa).

Before beginning the test procedure, ensure

that all cooktop section control valves are in

the “OFF” position, and all burner rings, burner

caps, and grates are properly positioned on the

top frame. Turn on the gas supply at the shut-off

valve.

Turn on the power supply to the range. Set the

time of day by pressing the “CLOCK” key and

then pressing either of the “TIME•TEMP” keys

(“+” or “-” keys) to advance or reduce the time in

the display in the desired setting.

Test each top burner separately by pressing

and turning one control knob at a time

counterclockwise to the “HIGH” position. All

ignitors will spark continuously, but only the

burner with gas flowing to it will ignite. It will take

approximately 4 seconds for ignition to occur,

at which time the ignitors will stop sparking. If

ignition does not occur within 4 seconds, turn

off the knob, wait for at least 2 minutes to allow

any gas to dissipate, then repeat this ignition

test. The control knob can then be rotated,

counterclockwise, from “HIGH” to “LOW” to

adjust the flame height (size) progressively.

Repeat the ignition test for all top burners.

When installed properly, the flame will be steady

and quiet. It will also have a sharp, blue inner

cone that will vary in length proportional to the

Verify Proper Operation for Electric

Ranges (RSE and MRES)

For RSE range top, rotate one surface element

knob at a time, counterclockwise, to the “HI”

position. Within 5 seconds, the element should

be fully energized and glowing red. Verify that

the residual heat indicator light comes on in

conjunction with the proper element, within

approximately 30 seconds. Return the knob

to the “OFF” position. Repeat for all surface

elements. (Note: The right front element is a

dual coil element. Clockwise rotation from

“LO” to “HI” will energize the inner coil only.

Counterclockwise rotation from “LO” to “HI”

will energize both the inner and outer coils

together).

For MRES range top, turn an element, tap the

“ON/OFF” key then tap the slew up/down area

of the desired element. The element will come

on at a setting of the number touched and may

be adjusted up or down by slewing up or down

on the appropriate key area with your finger.

To activate the Dual Outer Element, tap the

circle key at the end of the slew area (second

row), then tap or slew your finger up or down

on the second row of numbers. The outer ring

element will come on at a setting of the number

touched last. To turn the element off, tap the

“ON/OFF” key. You may turn off all active

elements at the same time by tapping twice on

the “CANCEL•SECURE” key located below the

controls

NOTE:

when the MRES unit is powered

on for the first time, the cooktop

control will go through a self-

check routine. when the self-

check is complete, the cooktop

control will go to SECURE mode.

See Use and Care Manual for

Secure Mode instructions.

Within 5 seconds, the element should be

fully energized and glowing red. Verify that

the residual heat indicator light comes on in

conjunction with the proper element, within

approximately 30 seconds.

RSd dual-Fuel Range Control knob

RSE Range Control knob

MRES “SLEw UP/dOwN” Range Control

NOTES:

If either the oven or cooktop does

not operate properly, follow these

troubleshooting steps:
1. Verify that power (all ranges)

and gas (RSd) are supplied to

the range.

2. Check the electrical

connections (all ranges) and

gas (RSd) supply to ensure

that the installation has been

completed correctly.

3. Repeat the above burner

ignition test (RSd).

4. If the appliance still does

not work, contact an

authorized dACOR service

company at (800) 772-7778.

do not attempt to repair the

appliance yourself. dACOR

is not responsible for service

required to correct a faulty

installation.

CANCEL • SECURE

ON/OFF

ON/OFF

ON/OFF

ON/OFF

NOTE:

Prior to operating the cooktop or

oven sections of the range, please

read the accompanying Use and

Care Manual carefully. Important

safety, service and warranty

information is contained within

this manual.