NIBCO High-Performance Butterfly Valve User Manual

Page 3

Advertising
background image

A H E A D O F T H E F L O W

®

www.nibco.com

NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227

TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455

www.nibco.com

3

®

Revised 8/22/2013

Installation, Operation and Maintenance Instructions

NIBCO 6822 and 7822 Series High Performance Butterfly Valves

Manual Gear Operator Adjustment
4.5

Verify cap screws attaching gear operator to the valve are securely tight. Rotate handwheel clockwise until it stops; disc

should be visually centered in the seat. If not, adjustment is necessary. Locate gear operator CLOSED stop set screw.

Unlock adjustment stop set screw by removing outer locking set screw or loosening locking nut. Rotate adjustment stop

set screw counter-clockwise 2 turns. Rotate handwheel until disc is visually centered in the seat. Rotate adjustment stop

set screw clockwise until it stops. Lock adjustment stop set screw by reinstalling outer locking set screw or tightening

locking nut. Rotate handwheel counter-clockwise opening valve. Rotate handwheel clockwise until it stops and check disc

to verify it is visually centered in the seat. If not, repeat adjustment procedure until it is.

4.6

Adjustment of OPEN stop can be achieved by similar adjustment of the OPEN stop set screw. The OPEN stop adjustment

is not critical; ±5° travel is adequate.

Electric Actuator Adjustment
4.7

Verify cap screws attaching the actuator to the valve are securely tight. Remove top cover of actuator exposing electrical

limit switches and cams. Use caution when working on this as electrical connections are exposed causing

potential electric shock hazard. Operate actuator to CLOSED position. Visually inspect the disc to assure it is centered

in the seat. If not, determine if valve in not fully closed or past closed. Unloosen CLOSED stop position cam set screw and

rotate slightly in the desired direction, then retighten set screw. Open valve, then operate valve to closed position. Visually

inspect the disc to assure it is centered in the seat. If not, repeat process until disc is centered in seat.

4.8

Adjustment of OPEN stop can be achieved by similar adjustment of the OPEN stop cam. The OPEN stop adjustment is not

critical; ±5° travel is adequate.

Pneumatic Actuator Adjustment
4.9

Verify cap screws attaching the actuator to the valve are securely tight. Operate actuator to CLOSED position. Visually

inspect the disc to assure it is centered in the seat. If not, adjustment is necessary. Locate actuator CLOSED stop set

screw. Unlock adjustment stop set screw by removing outer locking set screw or loosening locking nut. Rotate adjustment

stop set screw counter-clockwise 2 turns. Rotate valve until disc is visually centered in the seat. Rotate adjustment stop

set screw clockwise until it stops. Lock adjustment stop set screw by reinstalling outer locking set screw or tightening

locking nut. Operate actuator opening valve. Operate actuator CLOSED and check disc to verify it is visually centered in

the seat. If not, repeat adjustment procedure until it is.

4.10

Adjustment of OPEN stop can be achieved by similar adjustment of the OPEN stop set screw. The OPEN stop adjustment

is not critical; ±5° travel is adequate.

Advertising