I. Viton Gate & Bonnet O-ring

STD AND MSB 1.5” - 21” GATE VALVES

A. Tools and Materials Required:

1. Allen Wrench for 1.5”—14” Gate Valves
2. 1/2” Box Wrench for 16”—21” Gate Valves
3. O-Ring Pick
4. Rubber Gloves
5. Grease – Apezion L O-Ring Type
6. IPA

B. Procedure: Always wear Rubber Gloves when handling the Gate Valve

1. Vent station and pump corresponding to Gate Valve to atmosphere.
2. Actuate valve to Gate Open position.
3. For safety, remove air to actuator.
4. Remove bolts that hold Bonnet Actuator Assembly to body,

or for Quick-Clamp Bonnet, undo the clamp.

5. Pull out the Bonnet Actuator Carriage Assembly,

taking care not to move adjustment of linkage.

(Continued Next Page)

VALVE BODY

GATE ASSEMBLY &

STRONGBACK

LOWER AND UPPER LINKAGE

BONNET PLATE ASSEMBLY

ACTUATOR ASSEMBLY

ACTUATOR TOP WITH SENSORS

(OPENCLOSED)

Figure 1 - BONNET ACTUATOR CARRIAGE ASSEMBLY

SEPARATED FROM VALVE BODY