Power supply, Inputs – Datalogic Scanning SH2347 User Manual

Page 2

Advertising
background image

Power Supply


Power can be supplied to the scanner through the pins provided on the
25-pin connector used for communication with the host.

The power must be between 10 and 30 Vdc only.

13/9

25

1

VS

GND

CHASSIS

USER INTERFACE

GND

V+ (10 - 30 Vdc)

SCANNER


Inputs


The yellow LED is on when the External Trigger forces a current flow
through the EXT TRIG+ and EXT TRIG- pins.
This input is optocoupled and can be driven by both an NPN or PNP type
command. The connections are indicated in the following diagrams:

EXT TRIG+

18

19

+ 5V

SCANNER

EXTERNAL TRIGGER

Signal

V

30 Vdc max.

Vext

EXT TRIG-

Figure 2 - Input NPN command using external power


EXTERNAL TRIGGER

SCANNER

Signal

18

19

+ 5V

VS

9

25

GND

Ground

V

EXT TRIG+

EXT TRIG-

Figure 3 - Input NPN command using scanner power

18

19

+ 5V

SCANNER

EXTERNAL TRIGGER

30 Vdc max.

Vext

V

Signal

Ground

EXT TRIG+

EXT TRIG-

Figure 4 - Input PNP command using external power


EXTERNAL TRIGGER

SCANNER

18

19

+ 5V

VS

9

25

GND

Ground

V

Signal

EXT TRIG+

EXT TRIG-

Figure 5 - Input PNP command using scanner power




For DS1100, the general purpose input IN1 is used in the Standard
Application Program to store the code verifier (see “Store Verifier HW” in the
WinHost Help On Line)
. Use the input connections indicated in the figure
below. For DS2200, this input is not used.

13/9

17

VS

IN1 -

22

I/O REF

USER INTERFACE

Ground

V

SCANNER

47 K

Figure 6 - IN1 - Input command