Remote power pack cabling requirements – Star Headlight & Lantern STAR-PA RSK966P User Manual

Page 13

Advertising
background image

-10-

(Electrical Connections CONT’D)

Connecting the Remote Heads:

1. Cable is required to connect the power pack to your remote strobe heads. Cable can be

purchased from Star:

Length (ft)

Shielded Cable

SO Cable

w/Amp

w/Weatherproof

Connector

Connector

15

4415

3814-180”

20

4420

3814-240”

25

4425

3814-300”

30

4430

3814-360”

35

N/A

3814-420”

Length (ft)

Shielded Cable

SO Cable

w/Amp

w/Weatherproof

Connector

Connector

40

N/A

3814-480”

45

N/A

3814-540”

50

N/A

3814-600”

55

N/A

3814-660”

60

N/A

3814-720”

2. If you intend to use your own cable for connecting the remote heads, it must meet the following

specifications: It must be three-conductor with 600V insulation, it must be a minimum 18 AWG
for 0-30 ft. or 16 AWG for 31-60 ft., and it should be UV stabilized. Star does not recommend
the use of any cable length greater than 60 feet, as the resistance may cause a drop in voltage
resulting in inconsistent or complete loss of firing in the heads. Please use the Table below for
proper cable sizes.

0-20 ft.

21-30 ft.

31-60 ft

Input Power and

RP966:

Ground Wires

RP996:

16 AWG

14 AWG

14 AWG

12 AWG

12 AWG

10 AWG

Wires to

Remote Heads

18 AWG

18 AWG

16 AWG

Enable Wires

18 AWG

18 AWG

18 AWG

Remote Power Pack Cabling Requirements

3. If you are using your own cable and need connectors to attach the cable to the power pack,

order part #CK473. The #CK473 consists of one connector (30041-20) and three male
terminals (30042-16). This is also the replacement connector for any remote heads with the
white AMP connectors (NOT weatherproof).


4. The AMP connector, found on the cables, which mates to the CK473 is a kit #CK472. The

#CK472 consists of one connector (448) and three female terminals (30042-15).

5. If you need a weatherproof connector kit for your cable to attach to our remote strobe heads,

please order part #CK702. This kit contains one connector (30185-3), three female terminals
(30042-30), and three rubber seals (30186-2).

6. If you need to order a weatherproof connector kit for your strobe head to mate with the

connector on your cable (#CK702), please order part #CK703. This kit contains one connector
(30185-4), three male pins (30042-29), and three rubber seals (30186-2).

7. For good, reliable connections between the cable system and the strobe heads in

various weather and contamination conditions, it is strongly recommended that dielectric
grease be used on the connectors. It should be applied to the rear of the connectors,
where the wires enter, as well as into each terminal area where the connectors mate,
before joining the two connectors together. We have found this procedure to be
effective even under the most extreme of conditions. Do Not Seal The Connectors
Using Silicon Or RTV.

Advertising