(Electrical Connections CONT’D)

All Heads On and Off Together (High Power Only)

(This setup is typically used for most “On/Off” applications)

For this set up, only one On/Off switch (not included) is necessary.

1. Connect the black wire from the POWER connector to a good chassis ground.

2. Connect all three wires (red, black, and white) from the ENABLE plug and the red wire from

the POWER connector to a +12VDC power source through your On/Off switch.

3. The white wire from the POWER connector will be left unconnected for now. Once your

system is installed, the white wire will be used to program the flash pattern. Proceed to the
Pattern Selection section on page 7.

RP966/RP996

All Heads Activate Together

High Power Only

(Set Jumper in

High/Low Option Position)

WHITE
BLACK

1

SW1

OFF

R

E

D

GOOD

CHASSIS
GROUND

B

L

A

C

K

SP3860-1-15 LIGHTED SWITCH PANEL

(REAR VIEW)

ON

2

3

2

1

3

1

5

A

M

P

F

U

S

E

C

O

N

N

E

C

T

T

O

+

1

2

V

D

C

PLUGS

INTO

POWER

PAK

RED

ENABLE

CONNECTOR

POWER

CONNECTOR

Pattern Select:
Touch and release to +12VDC
to set pattern then tape off

WHITE

BLACK

RED

PLUGS

INTO

POWER

PAK

GOOD

CHASSIS
GROUND

All Heads On and Off Together (Low Power Only)

For this set up, only one On/Off switch (not included) is necessary.

1. Connect the black wire from the POWER connector and the white wire from your

ENABLE plug to a good chassis ground.

2. Connect the red and black wires from the ENABLE plug and the red wire from the POWER

connector to a +12VDC power source through your On/Off switch.

3. The white wire from the POWER connector will be left unconnected for now. Once your

system is installed, the white wire will be used to program the flash pattern. Proceed to the
Pattern Selection section on page 7.

RP966/RP996

All Heads Activate Together

Low Power Only

(Set Jumper in

High/Low Option Position)

RED

PLUGS

INTO

POWER

PAK

ENABLE

CONNECTOR

WHITE

BLACK

PLUGS

INTO

POWER

PAK

POWER

CONNECTOR

WHITE

RED

BLACK

Pattern Select:
Touch and release to +12VDC
to set pattern then tape off

1

SW1

OFF

R

E

D

GOOD

CHASSIS
GROUND

B

L

A

C

K

(REAR VIEW)

ON

2

3

GOOD

CHASSIS
GROUND

2

1

3

GOOD

CHASSIS
GROUND

1

5

A

M

P

F

U

S

E

C

O

N

N

E

C

T

T

O

+

1

2

V

D

C

Advertising