Set jumper in high/low option position), All heads on and off toge ther (high power only), All heads on and off together (low power only) – Star Headlight & Lantern STAR-PA RSK996P User Manual

Page 7: Enable connector power connector

Advertising
background image

-5-

All Heads On and Off Toge ther (High Power Only)

(This setup is typically used for most “On/Off” applications)

For this set up, only one On/Off switch (not included) is necessary.

1. Connect the black wire from the POWER connector to a good chassis ground.

2. Connect all three wires (red, black , and white) from the ENABLE plug and the red wire

from the POWER connector to a +12VDC power source through your On/Off switch.

3. The white wire from the POWER connector will be left unconnected for now. Once your

system is installed, the white wire will be used to program the flash pattern. Proceed to
the Pattern Selection section on page 8.





















































All Heads On and Off Together (Low Power Only)

For this set up, only one On/Off switc h (not included) is necessary.

1. Connect the black wire from the POWER connector and the white wire from your

ENABLE plug to a good chassis ground.

2. Connect the red and black wires from the ENABLE plug and the red wire from the

POWER connector to a +12VDC power source through your On/Off switch.

3. The white wire from the POWER connector will be left unconnected for now. Once your

system is installed, the white wire will be used to program the flash pattern. Proceed to
the Pattern Selection section on page 8.


RP966/RP996

All Heads Activate Together

High Power Only

(Set Jumper in

High/Low Option Position)

WHITE

BLACK

1

SW1

OFF

RED

GOOD

CHASSIS
GROUND

BLACK

ON

2

3

2

1

3

CONNECT TO +12 VDC

PLUGS

INTO

POWER

PAK

RED

ENABLE

CONNECTOR

POWER

CONNECTOR

Pattern Select:
Touch and release to +12VDC
to set pattern then tape off

WHITE

BLACK

RED

PLUGS

INTO

POWER

PAK

GOOD

CHASSIS

GROUND

SP3860-1-15 LIGHTED SWITCH PANEL

(REAR VIEW)

15 AMP

FUSE

RP966/RP996

All Heads Activate Together

Low Power Only

(Set Jumper in

High/Low Option Position)

RED

PLUGS

INTO

POWER

PAK

ENABLE

CONNECTOR

WHITE

BLACK

PLUGS

INTO

POWER

PAK

POWER

CONNECTOR

WHITE

RED

BLACK

Pattern Select:
Touch and release to +12VDC
to set pattern then tape off

1

SW1

OFF

RED

GOOD

CHASSIS
GROUND

BLACK

O N

2

3

GOOD

CHASSIS

GROUND

2

1

3

GOOD

CHASSIS
GROUND

CONNECT TO +12 VDC

SP3860-1-15 LIGHTED SWITCH PANEL

(REAR VIEW)

15 AMP

FUSE

Advertising