Installing, Continued – Desa CGD3924NR User Manual

Page 12

Advertising
background image

12

103343

14"
Min.

Combustible
Material

Non-Combustible Material

Hearth

5"
Min.

Combustible
Material

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set

18", 24", 30"
Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

INSTALLING

Continued

Floor Clearances

A. If installing appliance on the floor level, you must maintain the minimum

distance of 14" to combustibles (see Figure 8).

B. If combustible materials are less than 14" to the fireplace, you must install

appliance at least 5" above the combustible flooring (see Figure 9).

Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

If your installation does not meet the above minimum clearances, you must:
• operate the logs only with the flue damper open, OR
• raise the mantel to an acceptable height, OR
• remove the mantel.

Figure 7 - Minimum Mantel Clearances When Using Hood

Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

Advertising