Operating heater, Continued, Caution – Desa CGD3924NR User Manual

Page 20: Warning

Advertising
background image

20

103343

O

F

F

PIL

OT

O

N

L O

I H

REMOTE
OFF
ON

4. Press in and turn control knob clockwise

to the OFF position.

Figure 19 - Control Knob and Ignitor Button Location

Control Knob

Ignitor Button

Selector Switch in OFF Position

Flame
Adjustment
Knob

OPERATING

HEATER

Continued

5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the

floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.

6. Press in and turn control knob counterclockwise

to the PILOT position.

Press in control knob for five (5) seconds (see above).

Note:

You may be running this heater for the first time after hooking up to gas

supply. If so, the control knob may need to be pressed in for 30 seconds or
more. This will allow air to bleed from the gas system.

7. With control knob pressed in, press and release ignitor button. This will light

pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service person or gas supplier

for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure
on page 21.

Ignitor Electrode

Pilot Burner

Figure 20 - Pilot

9. Slightly push in and turn control knob counterclockwise

to the ON position.

10. Wait one minute and switch remote selector switch to the ON position to light burners.

11. Set flame adjustment knob to any level between HI and LO.

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob.

If control knob does not pop out when released, contact a qualified service

person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 4 through 8.

WARNING

Make sure the remote selector switch is in the OFF position when you are
away from home for long periods of time. Heater will come on automatically
with remote selector switch in the ON position.

Advertising