Operating heater, Inspecting burners, Continued – Desa CGD3924NR User Manual

Page 22

Advertising
background image

22

103343

OPERATING

HEATER

Continued

TEMP

STATUS

HI

LO

MAN

ON

AUTO

OFF

Increases Room
Temperature

Decreases Room
Temperature

Turns Burners
On and Off

Shows Current
Operation Mode

Shows Temperature Setting

Allows Burners to be Turned
On and Off with the Hand-
Held Remote Unit.

Figure 22 - Thermostat Hand-Held Remote Control Unit Selections

The log heater will
automatically cycle between
pilot and the heat setting that
has been selected.

3. Use the STATUS button on the hand-held remote control unit to see the operation

mode being used and the temperature setting selected. A red light will come on
beside the operation mode being used when the status button is pressed.

4. To turn the burners off when operating in the MANUAL mode, press the OFF

button. If operating in the auto mode, press the manual button, then press the
OFF button The pilot will remain lit.

IMPORTANT:

To turn the pilot off, manually turn the control knob on the heater

to the OFF position or set remote selector switch to OFF position.

Thermocouple

Pilot Burner

Figure 23 - Correct Pilot Flame Pattern

Figure 24 - Incorrect Pilot Flame

Pattern

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 24

• turn heater off (see To Turn Off Gas to Appliance, page 21)
• see Troubleshooting, pages 23 through 26

Thermocouple

Pilot Burner

Advertising