Specifications, User manual – SurgeX SX-AX20E User Manual

Page 34

Advertising
background image

User Manual

Firmware Version v2.04.281

© 2015 SurgeX/Electronic Systems Protection, Inc. | Technical Support: 800-645-9721 | surgex.com 34

14. Specifications

Parameter

Specification

Load Rating

15/20 Amps at 120 Volts (SX-AX15E / SX-AX20E)

Power Requirement (no load)

5 Watts

Surge Let-through Voltage (6000 Volt Surge)

0 Volts

UL 1449 Adjunct Classification Test Results

1000 Surges, 6000 Volts, 3000 Amps, B3 pulse; measured
suppressed voltage, 170 Volts; no failures

Maximum Applied Surge Voltage

6000 Volts *

Maximum Applied Surge Current

Unlimited (due to current limiting) *

Maximum Applied Surge Energy

Unlimited (due to current limiting) *

Endurance (C62.41-1991 category B3 pulses)

1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000

EMI/RFI Filter

Normal mode (50Ω load)

40 dB@100 KHz, 50dB@300 KHz, 50 dB@3 MHz, 50 dB@30 MHz

Common Mode (50Ω load)

18dB@300 KHz, 30 dB@1 MHz, 50 dB@5 MHz, 50 dB@20 MHz

Under-Voltage Auto Shutdown

Adjustable from 80V to 110V, or disabled.

Over-Voltage Auto Shutdown

Adjustable from 130V to 160V

Over-Current Auto Shutdown

Adjustable from 1A to 20A, or disabled.

Over-Temperature Auto Shutdown

Adjustable from 70 to 100°F, or disabled.


Measurement Accuracy

Voltage

± 1% from 90 – 160 VRMS

Current

± 1% from 0.1 – 20 ARMS (Resistive)

Power

± 5% from 0.1 – 2400 WRMS (Resistive)

Energy

± 5% kWh

Temperature

± 5.3C from -25 – 105C

Network Port

10/100 Ethernet connection on Female RJ-45, Auto Negotiating with
10/100/1000 network connections with Link and Activity LEDs

Serial Port

RS-232 on Female 9-pin D-subminiature, DCE

Temperature Sensor Input

2 x screw terminal

Auxiliary Relay Outputs

(2) 3 x screw terminal

Contact Closure Input

2 x screw terminal

Dimensions

19” W x 12.25” D x 1.75” H (Single Rack Space)

Weight

13 lb.

Temperature Range:

5C to 35C

Humidity Range

0% to 95% R.H. Non-condensing

Agency Listings

ETL Certified to UL 1449 3

rd

Edition

ETL Certified to UL 1283 5

th

Edition

ETL Certified to CSA 22.2 No. 8-M1986 (R2008)

* 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41

*CAUTION: Do not install this device if there is not at least 10 meters (30 feet) or more between the electrical outlet and the electrical service panel.