www.desatech.com

124452-01A

10

Minimum
Noncombustible
Material

Minimum
Noncombustible
Material Height

Distances to
Underside of
Mantel

Top of
Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

8"

(A)

8" 14" 17" 20"

All minimum
distances are
in inches

Log Set
All Models

2 1/2"

6"

8"

10"

IMPORTANT: If you cannot meet these mini-
mum clearances, you must operate heater
with chimney flue damper open. Go to Install-
ing Damper Clamp Accessory for Vented
Operation
, page 11.

If Using Mantel

You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.) must
be at least 1/2" thick. With sheet metal, you
must have noncombustible material behind it.
Noncombustible material must extend at least
8" up. See Figure 5, page 9, and Figure 6 for
minimum clearances.
IMPORTANT: If you cannot meet these mini-
mum clearances, you must operate heater
with chimney flue damper open. Go to Install-
ing Damper Clamp Accessory for Vented
Operation,
page 11.

INSTALLATION

Continued

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clearances
listed below, you will need a hood.
You must meet the minimum clearances
between the mantel shelf and the top of the
fireplace opening as shown in Figure 6.

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

Figure 6 - Minimum Mantel Clearances

Without Using Hood