INSTALLATION

Continued

Equipment Shutoff Valve

Propane/LP
Supply Tank

Control Valve
Location

Figure 16 - Checking Gas Joints

(Natural Gas Only)

Gas
Meter

Equipment Shutoff Valve

Control Valve Location

Figure 15 - Checking Gas Joints

(Propane/LP Gas Only)

3. Check all joints from gas meter (natural

gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
joints. Bubbles forming show a leak.

4. Correct all leaks at once.

INSTALLING LOGS

WARNING: Failure to position

the parts in accordance with these

diagrams or failure to use only

parts specifically approved with

this heater may result in property

damage or personal injury.

CAUTION: After installa-

tion and periodically thereafter,

check to ensure that no flame

comes in contact with any log.

With the heater set to High, check

to see if flames contact any log.

If so, reposition log according to

the log installation instructions

in this manual. Flames contact-

ing log will create soot.

It is very important to install these logs exactly
as instructed. Do not modify logs. Only use
logs supplied with heater.
1. Place grate into square holes on heater

base as shown in Figure 17.

2. Place front log on burner so that it sits

between grate fingers and burner (see
Figure 17).

Figure 17 - Installing Grate and Logs

PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure

14, page 14).

2. Open main gas valve located on or near

gas meter for natural gas or open pro-
pane/LP supply tank valve.

3. Make sure control knob of heater is in the

OFF position.

4. Check all joints from gas meter (natural

gas) or propane/LP supply to equipment
shutoff valve (see Figure 15 or 16). Apply
a commercial leak detection solution to all
joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operation page 16).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to

Appliance, page 17).

Grate

Heater Base

Front Log

The Front Log Should Be
Centered Left To Right.