TROUbLESHOOTING

Continued

OBSERVED PROBLEM

Slight smoke or odor during
initial operation

Moisture/condensation no-
ticed on windows

Heater produces a whistling
noise when burner is lit

White powder residue forming
within burner box or on adja-
cent walls or furniture

Heater produces a clicking/
ticking noise just after burner
is lit or shut off

REMEDY

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 19)

2. Replace gas regulator
3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation require-
ments (page 5)

1. Turn control knob to LO

position and let warm up
for a minute

2. Operate burner until air is

removed from line. Have
gas line checked by local
natural or propane/LP gas
company

3. Observe minimum instal-

lation clearances (see
page 8)

4. Clean burner (see Cleaning

and Maintenance, page 19)
or replace burner orifice

1. Turn heater off when us-

ing furniture polish, wax,
carpet cleaners or similar
products

1. This is normal with most

heaters. If noise is exces-
sive, contact qualified ser-
vice person

POSSIBLE CAUSE

1. Not enough air

2. Gas regulator defective
3. Residues from manufac-

turing processes and log
curing

1. Not enough combustion/

ventilation air

1. Turning control knob to HI

position when burner is
cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

1. When heated, vapors from

furniture polish, wax, carpet
cleaners, etc. may turn into
a white powder residue

1. Metal expanding while

heating or contracting while
cooling

Advertising