TROUbLESHOOTING

WARNING: Turn off and unplug heater and let cool before servicing.

Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or

wet

3. Broken ignitor cable
4. Bad piezo ignitor
5. Ignitor electrode broken
6. Ignitor electrode positioned

wrong

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is

not correct

OBSERVED PROBLEM

When control knob is pressed
in and turned to PILOT, there
is not spark at ODS/pilot

When control knob is pressed
in and turned to PILOT, there
is spark at ODS/pilot but no
ignition

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing. Keep
ignitor cable dry

3. Replace valve
4. Replace valve
5. Replace pilot
6. Reposition ignitor electrode

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while

in PILOT position

4. Continue holding down con-

trol knob. Repeat igniting op-
eration until air is removed

5. Contact local propane/LP

gas company

6. Clean ODS/pilot (see Clean-

ing and Maintenance, page
19) or replace ODS/pilot
assembly

7. Replace gas regulator

Advertising