Product identification, Safety – Desa VyS18NC User Manual

Page 4

Advertising
background image

www.desatech.com

124452-01A

4

SAFETy

Continued

Figure 1 - Product Idetification

11. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.

12. This heater needs fresh, outside air ven-

tilation to run properly. This heater has an
Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the
heater if not enough fresh air is available.
See Air for Combustion and Ventilation,
page 5. If heater keeps shutting off, see
Troubleshooting, page 20.

13. Do not run heater

• where flammable liquids or vapors are

used or stored

• under dusty conditions

14. Do not use this heater to cook food or burn

paper or other objects.

15. Do not use heater if any part has been ex-

posed to or under water. Immediately call
a qualified service technician to inspect
the room heater and to replace any part
of the control system and any gas control
which has been under water.

16. Do not operate heater if any log is broken.

Do not operate heater if a log is chipped
(dime-sized or larger).

17. Turn heater off and let cool before servic-

ing. Only a qualified service person should
service and repair heater.

18. Operating heater above elevations of

4,500 feet could cause pilot outage.

19. Provide adequate clearances around air

openings.

PRODUCT

IDENTIFICATION

2. Do not place propane/LP supply tank(s)

inside any structure. Locate propane/LP
supply tank(s) outdoors (propane/LP
units only).

3. To prevent performance problems, the

use of a propane/LP tank of less than
100 lbs. capacity is not recommended
(propane/LP units only).

4. If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not

use any phone in your building

• immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

5. This heater shall not be installed in a

bedroom or bathroom unless installed as
a vented appliance (see Installing Damper
Clamp Accessory for Vented Operation
,
page 11). This gas log set may not be
installed as a vented appliance in a bed-
room or bathroom in the Commonwealth
of Massachusetts.

6. Do not burn solid-fuel in a masonry or

UL127 factory-built fireplace in which a
vent-free room heater is installed.

7. Before installing in a solid fuel burning fire-

place, the chimney flue and firebox must
be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner.
Creosote will ignite if highly heated. A dirty
chimney flue may create and distribute
soot within the house. Inspect chimney
flue and firebox for damage. If damaged,
repair flue before operating heater.

8. If fireplace has glass doors, never operate

this heater with glass doors closed. If you
operate heater with doors closed, heat
buildup inside fireplace will cause glass to
burst. Make sure there are no obstructions
across openings of fireplace.

9. This log heater is designed to be smoke-

less. If logs ever appear to smoke, turn off
heater and call a qualified service person.

Note: During initial operation, slight smok-
ing could occur due to log curing and
heater burning manufacturing residues.

10. To prevent the creation of soot, follow

the instructions in Cleaning and Mainte-
nance,
page 18.

Heater Base