Operating heater, Lighting instructions, Continued – Desa VP1600C User Manual

Page 18

Advertising
background image

18

100751

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information at the top of page 17.

2. Make sure manual shutoff valve is fully open.

3. Turn thermostat control knob on left side of heater clockwise

Clockwise

to the

OFF position.

OPERATING

HEATER

Models VP1600IT

and VP2200IT

Continued

4. Wait five minutes to clear out any gas. Then smell for gas, including near

the floor. If you smell gas, STOP! Follow “B” in the safety information at
the top of page 17. If you don’t smell gas, go to the next step.

5. Turn thermostat control knob on left side of heater counterclockwise

C-clockwise

to the PILOT position. Press in thermostat control knob for 5

seconds.

Note:

You may be running this heater for the first time after hooking up

to gas supply. If so, you may need to press in thermostat control knob for
30 seconds. This will allow air to bleed from the gas system.

• If thermostat control knob does not pop up when released, contact a

qualified service person or gas supplier for repairs.

6. Keep thermostat control knob pressed in while pushing down and releasing

the ignitor button. This will light pilot. If necessary, continue to press
ignitor button until pilot lights.

If pilot does not light

• turn thermostat control knob clockwise

Clockwise

to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, pages 26 through 29
• contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see
Manual Lighting Procedure
, page 20.

7. Keep thermostat control knob pressed in for 30 seconds after lighting pilot.

After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. This heater has a safety

interlock system. Wait one minute before lighting pilot again.

8. Turn thermostat control knob counterclockwise

C-clockwise

to the desired

heating level. The plaque directly above the pilot should light.

Figure 17 - Thermostat Control Knob In The OFF Position

IGNITOR

PILOT

LO

OFF

HI

1

2

3

4

Thermostat
Control Knob

Plaque
Control Knob

Ignitor Button