SPECIFICATIONS

VP1600IT

VP2200IT

BTU (Variable)

6,000-16,000

6,500-22,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

Heater

24

32

Shipping

29

38

VP1600C

VP2600C

BTU (Variable)

6,000/11,000/16,000

6,000/16,000/26,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

Heater

22

30

Shipping

27

36

When gas pressure is too low

• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.

SERVICE

HINTS

SERVICE

PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this
manual. Send a check for $5.00 payable to DESA International.