Trouble- shooting – Desa VP1600C User Manual

Page 27

Advertising
background image

27

100751

REMEDY

1. Turn on gas supply or

open manual shutoff
valve.

2. Press in control knob

while turning to PILOT/
IGN position (non-
thermostat models only).
Press in thermostat
control knob while
turning to PILOT/IGN
position (thermostat
models only)

3. Continue holding down

control knob. Repeat
igniting operation until
air is removed.

4. Contact local propane gas

company.

5. Clean ODS/pilot (see

Cleaning and Mainte-
nance
, page 26) or
replace ODS/pilot
assembly.

6. Replace gas regulator.

7. Turn thermostat control

knob to pilot position.

OBSERVED
PROBLEM

When control knob is
pressed in and turned
to the PILOT/IGN
position, there is spark
at ODS/pilot but no
ignition (non-thermo-
stat models only).

When ignitor button is
pressed in, there is a
spark at ODS/Pilot but
no ignition (thermo-
stat models only).

TROUBLE-

SHOOTING

Continued

ODS/pilot lights but
flame goes out when
control knob is
released.

POSSIBLE
CAUSE

1. Gas supply turned off or

manual shutoff valve
closed.

2. Control knob not pressed

in while being turned to
PILOT/IGN position
(non-thermostat models
only).
Thermostat control knob
not pressed in (thermostat
models only).

3. Air in gas lines when

installed.

4. Depleted gas supply

5. ODS/pilot is clogged.

6. Gas regulator setting is

not correct.

7. Thermostat control knob

is not in pilot position
(thermostat models only).

1. Control knob not fully

pressed in.

2. Control knob not pressed

in long enough.

3. Manual shutoff valve not

fully open.

4. Thermocouple connection

loose at control valve.

5. Pilot flame not touching

thermocouple, which
allows thermocouple to
cool, causing pilot flame
to go out. This problem
could be caused by one or
both of the following:
A) Low gas pressure
B) Dirty or partially
clogged ODS/pilot

6. Thermocouple damaged.
7. Control valve damaged.
8. Safety interlock system

has been triggered (ther-
mostat models only).

1. Press in control knob

fully.

2. After ODS/pilot lights,

keep control knob pressed
in 30 seconds.

3. Fully open manual shut-

off valve.

4. Hand tighten until snug,

then tighten 1/4 turn more.

5. A) Contact local propane

gas company.

B) Clean ODS/pilot (see
Cleaning and Mainte-
nance
, page 26) or
replace ODS/pilot
assembly.

6. Replace thermocouple.
7. Replace control valve.
8. Wait one minute for safety

interlock system to reset.
Repeat ignition operation.

Continued