100751

OBSERVED
PROBLEM

Burner(s) does not
light after ODS/pilot is
lit.

Delayed ignition of
burner(s)

Burner backfiring
during combustion.

Burner plaque(s) does
not glow.

Slight smoke or odor
during initial opera-
tion

Heater produces a
clicking/ticking noise
just after burner is lit
or shut off.

REMEDY

1. Clean burner orifice(s)

(see Cleaning and
Maintenance
, page 26) or
replace burner orifice(s).

2. Replace burner orifice(s).

3. Contact local propane gas

company.

1. Contact local propane gas

company.

2. Clean burner orifice(s)

(see Cleaning and
Maintenance
, page 26 or
replace burner orifice(s).

1. Clean burner orifice(s)

(see Cleaning and
Maintenance
, page 26) or
replace burner orifice(s).

2. Replace burner.
3. Replace gas regulator.

1. Replace burner.
2. Contact local propane gas

company.

3. Turn control knob until it

locks at desired setting.

1. Problem will stop after a

few hours of operation.

1. This is common with

most heaters. If noise is
excessive, contact
qualified service person.

POSSIBLE
CAUSE

1. Burner orifice(s) is

clogged.

2. Burner orifice(s)

diameter is too small.

3. Inlet gas pressure is too

low.

1. Manifold pressure is too

low.

2. Burner orifice(s) is

clogged.

1. Burner orifice(s) is

clogged or damaged.

2. Burner damaged.
3. Gas regulator defective.

1. Plaque damaged.
2. Inlet gas pressure is too

low.

3. Control knob set be-

tween locked positions.

1. Residues from manu-

facturing processes

1. Metal expanding while

heating or contracting
while cooling.

TROUBLE-

SHOOTING

Continued

Advertising
This manual is related to the following products: