Operating heater, Inspecting burner, Manual lighting procedure – Desa VP1600C User Manual

Page 24

Advertising
background image

24

100751

GRH/OV 007

GOOD PILOT/LP

Thermocouple

Pilot Burner

Figure 23 - Correct Pilot Flame Pattern

Thermocouple

GRH/OV 008

BAD PILOT/LP

Pilot Burner

Figure 24 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 24

• turn heater off (see To TurnOff Gas to Appliance, page 20 [models

VP1600IT and VP2200IT] or page 24 [models VP1600C and VP2600C])

• see Troubleshooting, pages 26 through 29

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, pages 21 and 22.

2. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

OPERATING

HEATER

Models VP1600C

and VP2600C

Continued

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.