Vortech Alpha H3 Hummer - 2008 User Manual

Page 21

Advertising
background image

P/N: 4GN020-015

©2008 Vortech Engineering, LLC

All Rights Reserved, Intl. Copr. Secured

20OCT08 v2.0 08HummrH3(4GNv1.0)

15

7. CHARGE COOLER INSTALLATION, cont’d

Fig. 7-g

R.

Secure all hose connections at this time

using the supplied nylon ratchet clamps.

Make sure that all hoses are routed and

secured away from hot or moving parts.

S.

Using the supplied butt connector, attach the

supplied length of wire to the poitive (green)

wire on the water pump. Route the wire to the

power distribution box (PDB) located on the

driver side. Trim the wire so that it just

reached the PDB. Connect the supplied fuse

holder to the end of the wire. Attach the

trimmed piece of wire to the opposite side of

the fuse holder. Locate the fuel pump relay.

Using the mini ATC fuse tap and the supplied

femal spayed connector attach the wire to

terminal #87 on the relay. (see Fig. 7-g)

T.

Attach the supplied ring terminal to the water

pump ground wire. Secure the ground wire to

the inner fender using the supplied M8 fas-

tener.

U.

Fill the CAC coolant using a 25%/75% anti-

freeze/water mix. Fill through the surge tank

fill port located on the CAC.

Advertising