24

107205

DIRECT-VENT FIREPLACE

For more information, visit www.desatech.com

OPERATING
FIREPLACE

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

TO TURN OFF GAS

TO APPLIANCE

A. This appliance is equipped with an

ignition device which automatically
lights the pilot. Do not try to light the
pilot by hand.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow
the gas supplier's instructions.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don't try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire
or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

1.

STOP! Read the safety information
in column one.

2.

Open lower louver panel.

3.

Turn wall switch to “OFF”.

4.

Turn off all electric power to the
fireplace.

5.

Turn the equipment shutoff valve
clockwise

to the OFF position

(see Figure 50). Do not force.

6.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column one. If you don't
smell gas, go to the next step.

7.

Turn equipment shutoff valve counter-
clockwise

to the ON position.

8.

Turn on all electrical power to the
appliance.

9.

Turn the wall switch to the ON
position.

10. Visually locate the pilot. The ignitor

should begin to spark and the main
burner should ignite once flame ap-
pears at pilot.
• If lighting the appliance for the

first time each season, it may take
several attempts before the supply
gas can reach the pilot and main
burners.

• If the appliance will not stay lit af-

ter several attempts, follow the in-
structions To Turn Off Gas To Ap-
pliance
, column 3, and call your
service technician or gas supplier.

11. Close lower louver panel.

Figure 50 - Turning the Equipment Shutoff
Valve to the OFF position

Equipment Shutoff Valve

Control Valve

1.

Turn off the wall switch.

2.

Turn off all electric power to the ap-
pliance if service is to be performed.

3.

Open control access panel.

4.

Turn equipment shutoff valve clock-
wise

Clockwise

to “OFF”. Do not force.

5.

Close control access panel.

Figure 51 - Pilot

Pilot
Assembly

Ignitor/Sensor

OPTIONAL REMOTE

OPERATION

Note:

The WRC receiver and hand-held

remote control kit must be purchased sepa-
rately (see Accessories,
page 34). Follow
installation instructions on page 21.
1.

Turn equipment shutoff valve to ON
position. You can now turn the
burner on and off with the hand-held
remote control unit.

IMPORTANT:

Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

2.

Press the ON/OFF button to turn the
burner on and off.

Advertising